How to deal with high impedance voltage source? Increase the load capacity?

Hardware design
novembre 05, 2020 by Shelley 537

There is a sensor whose internal resistance is as high as 3~5M, and the voltage is roughly 60V. Now we need to measure this voltage, but once the voltage divider is connected, the voltage on the load drops to mV level immediately, and it is definitely not accurate. How to deal with this situation?

Tutti i commenti

user image

Mayer postato su November 5, 2020

Refer to the internal resistance of the voltage range input circuit of the digital voltmeter, which is a few M levels.

0
user image

Aishwarya postato su November 5, 2020

The voltage divider resistance you use is too small, at least about 5M, and the input impedance of the voltmeter should be very high.

0
user image

Niki postato su November 5, 2020

Isn’t it possible to use a voltage follower to transform the impedance first and then measure the voltage?